MAIN FEATURES
The IdroStat electrical panel commands and controls electric pumps for irrigation systems for submerged pumps, even large ones, and/or withdrawal from deep wells.
The IdroStat series panels represent a simple and reliable electromechanical solution for the control of submerged electric pumps.
The IdroStat family of devices performs an impedance start-up of the electric pumps
THE ADVANTAGES
- Integrated voltmeter and ammeter
- Lower starting current than a direct start
- Auxiliary circuit in low voltage
- Simplicity in the implementation of non-routine maintenance
MANUFACTURING SPECIFICATIONS
- Control panel made in metal box
- Protection class IP54 (IP66 on request)
- Colour RAL7035
TECHNICAL SPECIFICATIONS
- Electromechanical panel;
- Power supply 3F+T 400V±10% 50/60Hz;
- Auxiliary circuit voltage 24V±10% 50/60Hz;
- Selector for manual-switch-off-automatic operation;
- Automatic operation through: 1 double-chamber float and/or 1 pressure switch;
- Engine running indicator light;
- Engine running indicator light in protection;
- Voltmeter;
- Ammeter;
- Contactors sized in AC3;
- Stator reactor 5 start-ups per hour of which 2 consecutive;
- Adjustable reactance timer;
- Transformer in Class II;
- Thermal protection internally resettable;
- Motor protection fuses;
- Auxiliary protection fuses;
- General door lock disconnector;
- Terminal block;
- Wiring diagram and CE declaration