Sprinkler control room demonstration cart Idroschool 3: a mobile unit that replicates an alarm valve station for wet and dry sprinkler systems, designed for functional testing and training activities (in combination with Idroschool 1).

Specifically designed for training centers in compliance with DM 1 September 2021

Sprinkler control station demonstration cart Idroschool 3 is a training and testing solution that allows realistic and controlled reproduction of the operating logic of an alarm control station for both wet and dry sprinkler networks. The main hydraulic, pneumatic and electrical components necessary to perform operational tests, intervention simulations and device behavior checks are assembled on the cart.
To complete the demonstration of discharge devices, Idroschool 3 is designed to be combined with the Idroschool 1 cart, on which several types of sprinklers are installed: this makes it possible to observe the functional chain “control station–network–sprinkler” and correctly test alarm signals and operating conditions.
Thanks to its cart structure, Idroschool 3 is suitable for contexts requiring practical tools for training and verification: technical courses, internal demonstrations, personnel training and testing or functional diagnosis activities on components equivalent to those installed in the field. The sprinkler control station demonstration cart facilitates understanding of the differences between wet and dry systems and makes analysis of start-up, pressurization, alarm and discharge conditions more immediate.

Key Features

  • Sprinkler control station demonstration cart with assembled components to simulate an alarm control station
  • Management of wet and dry sprinkler networks
  • Designed for operation testing and training activities
  • Prepared to be used together with Idroschool 1 (sprinkler demonstration)
  • Mobile cart structure with integrated hydraulic and electrical components

Advantages

  • Practical tool for technical training: demonstrates the logic and components of a sprinkler control station immediately
  • Repeatable functional tests in a controlled environment, without intervention on actual systems
  • Rapid understanding of the differences between wet system and dry system
  • Facilitates checks and simulations on valves, pressures, alarms and operational maneuvers

Technical specifications

  • Ability to supply sprinklers via swivel connection DN45 – 1″1/2
  • Cart structure with integrated electrical panel and network components

Customizations

  • Integration and combined use with Idroschool 1 for demonstration of different types of sprinklers
  • Configurations and training equipment according to use (training, commercial demonstration, internal training)

Applications