Case Study
ALMA Srl Fire Safety Training Center

ALMA Srl has chosen Idroelettrica to build a training center dedicated to fire protection maintenance technicians at its headquarters. The project stems from the desire to replicate a proven training model, using real equipment and configurations that align with client requirements and regulatory requirements.

Client requirements

During a visit to the Idroelettrica headquarters, A.L.M.A. officials were able to tour our recently inaugurated training center, which operates in partnership with the M.A.I.A. association. This led to a request to establish a similar center at their headquarters, in order to expand and strengthen the training offerings in the region, thereby highlighting a long-standing aspect of ALMA’s work: training.

Idroelettrica's proposal

To meet the requirements set forth in the Ministerial Decree of September 1, 2021 (as you indicated, “Decree-Law of September 1, 2021”) regarding the setup of training equipment, Idroelettrica has proposed a custom-designed FIREBOX for delivering courses on:
  • sprinkler systems
  • fire suppression pressurization systems
  • fire hydrant network
Suggested configuration:
  • 1 electric main pump
  • 1 main diesel pump
  • 1 Jockey Pump
  • Custom skid for fire hydrant and sprinkler systems

The Result

The project presented a stimulating challenge for Idroelettrica’s technical staff, particularly due to the “custom” nature of the system and the attention required by the training environment. Attention to detail made all the difference, transforming the supply into a comprehensive professional service, delivered by deploying specialized equipment and leveraging experience gained over the years.
Davide Zunino A.L.M.A. s.r.l. - Idro-elettrica S.p.A.
Davide Zunino
Owner of A.L.M.A. s.r.l.
I am convinced that our center will become a new hub for the training and continuing education of fire safety professionals in the Northwest, thanks in part to our collaboration with Idroelettrica and its products

Project specifications

Product employed

Idroelettrica Spa Training Products 02 29 20241022100135016
Sprinkler control room demonstration cart Idroschool 3: a mobile unit that replicates an alarm valve station for wet and dry sprinkler systems, designed for functional testing and training activities (in combination with Idroschool 1).
Ico Grup - Idro-elettrica S.p.A.

pump-set

1 Elettropompa1 Motopompa1 Pompa Jockey
Ico Pump - Idro-elettrica S.p.A.

Pump Type

5,5 kW + 33 kW + 1,5 kW
Ico Inst - Idro-elettrica S.p.A.

Installation

Sottobattente

Ico Prest - Idro-elettrica S.p.A.

Hydraulic Performance

Flow rate: 20 m³/h

Head: 72 m.w.c.

Ico Norm - Idro-elettrica S.p.A.

Applicable standards

Download