Eurofire SOM

Eurofire SOM - Idroelettrica Spa

Eurofire SOM is an automatic fire pump-set featuring submerged main electric pumps and a submerged jockey pump, ideal when inlet conditions and space constraints make traditional solutions not feasible.

  • Flow rate Q up to 150 m³/h
  • Head H up to 166 m.w.c.
  • Electric Pumps up to 30 kW
 

Eurofire SOM is a UNI EN 12845-compliant pump-set solution designed to mitigate common inlet-related installation issues, such as elevation differences, high head losses, and unfavorable piping lengths. The series uses submersible service pumps (main and jockey), a configuration particularly suitable when the technical room is too small to host a conventional horizontal pump set.
Submersible electric pumps, as referenced by the standard (UNI EN 12845 10.6.1), should be considered a solution to be adopted when it has not been possible to provide horizontal pumps with positive suction or Vertical Turbine Pumps (VTP) solutions. In this context, Eurofire SOM provides a compact, automatic system oriented toward continuous service, with sized and configured components in compliance with UNI EN 12845 requirements, including controls, protections, and discharge line.

Key Features

  • Series performance: Flow rate Q up to 150 m³/h; Head H up to 145 m.w.c.
  • Electric pump up to 30 kW
  • Main submersible electric pumps + submersible jockey pump
  • Solution suitable for inlet constraints and installation space limitations
  • Design and components compliant with UNI EN 12845

Advantages

  • Simplified installation for NPSH/suction issues or unfavorable piping
  • Compact dimensions: suitable for small technical rooms
  • Automatic operation with dedicated command and control management
  • Cost-effective solution compared to more complex alternatives, where applicable by standard

Technical specifications

  • Components compliant with UNI EN 12845 requirements
  • Main multistage centrifugal submersible pumps with motor connection according to NEMA standards (UNI EN 12845 10.1)
  • Submersible electric motors
  • Electric control panels with BLACK BOX controller
  • Delivery columns sized according to UNI EN 12845 13.2.3, with inspectable check valves
  • Submersible jockey pump complete with control circuit

Customizations

  • Sizing based on project (Q/H) within the limits of the EUROFIRE SOM range
  • Panel configuration and signals based on specifications and system integration
  • Selection of accessories and line components based on installation and UNI EN 12845 requirements

Applications

Shopping Centers

Cinemas and theatres

Hotel complexes

Critical infrastructure

Industries

Healthcare facilities

Residential secto

School facilities

Oil & Gas

Case Study