Idroschool 1

Idroschool 1 - Idroelettrica Spa

Sprinkler types demonstration trolley Idroschool 1: mobile unit with the main sprinkler configurations assembled on manifold, designed for educational activities, demonstrations and testing in a controlled environment.

Specifically designed for training centers in compliance with DM 1 September 2021

Sprinkler types demonstration rack Idroschool 1 is a technical-educational tool designed to provide an immediate and practical demonstration of the main types of sprinklers used in fire protection systems. Various nozzle models and related connection components (manifold, valves, reducers, and fittings) are assembled on the rack to allow for clear explanations of dimensional differences, connections, and typical installation configurations.
Thanks to its mobile structure, Idroschool 1 is suitable for training courses, personnel training activities, on-site demonstrations or technical events, and practical tests aimed at understanding the components. The water supply is provided via a DN45 – 1”1/2 swivel connection, which allows for quick connection for simulations and testing.
Within the Idroschool program, this rack can also be used as a support for integrated demonstration activities with racks dedicated to the control unit and alarm valves (e.g., when required by the customer’s configuration and setup), offering a complete overview of the “control unit–network–sprinkler” chain.

Key Features

  • Sprinkler types demonstration trolley with assembly of the main types of sprinkler heads
  • Mobile wheeled structure with manifold and line components
  • Designed for rapid supply via DN45 – 1”1/2 swivel connection
  • Selected components to clearly show differences between sprinklers and their connections

Advantages

  • Effective support for training and technical demonstrations on sprinklers
  • Organized and portable setup: ideal for classroom, workshop or demo area
  • Possibility of practical tests and hands-on explanations on connections and sizes
  • Reduces the need to operate on actual systems during training activities

Technical specifications

  • Supply via DN45 – 1”1/2 swivel connection
  • Structure:
    • Support frame in painted steel
    • Wheels for movement D100
  • Line and fittings:
    • 2” sprinkler manifold
    • fittings (elbow, reducers) and shut-off valves as per component list

Customizations

  • Possibility to configure the sprinkler equipment according to training/demonstration needs (sizes and models)
  • Integration with other training trolleys in the Idroschool line for complete training programs

Applications