Eurofire

Eurofire - Idroelettrica Spa

Eurofire is a range of prefabricated, modular pumping units engineered to provide reliable, space‑saving systems in accordance with UNI EN 12845, suitable for installation in confined technical rooms.

  • Flow rate Q up to 800 m³/h
  • Head H up to 159 m w.c.
  • Electric Pumps up to 250 kW
  • Diesel Pumps up to 255 kW on NA curve

Eurofire is a series of UNI EN 12845‑compliant fire pump sets based on an horizontal centrifugal main pumps (end‑suction, back‑pull‑out). The system is conceived as a versatile assembly of two or more autonomous modules: each module is a prefabricated pump set mounted on a metal base and supplied complete with accessories, valves, automation, electrical panels and an interconnectable discharge manifold. This modular architecture makes Eurofire particularly suitable where high performance must be combined with installation constraints, allowing the station to be configured progressively and in an orderly manner. Safety is emphasised through protected components (with safety guards) and an advanced control suite designed for system integration and supervision.

Key Features

  • EUROFIRE series performance: Flow rate Q up to 800 m³/h, Head H up to 160 m w.c.
  • Electric pump up to 315 kW
  • Diesel pump up to 266 kW (on NA curve)
  • Autonomous pump set modules on baseplate, with safety guard (UNI EN 12845:2020 10.0)
  • Manifold/delivery line pre-arranged for coupling between modules

Advantages

  • Modular and flexible system: ideal for confined spaces and space constraints
  • Simpler installation thanks to prefabricated modules ready for integration
  • Greater operational continuity: multi-module configurations and organized component management
  • Advanced control with electronics and automation dedicated to firefighting service

Technical specifications

  • Baseplate in robust welded, painted steel profiles, movable by forklift or crane
  • Available versions: POSITIVE SUCTION HEAD and SUCTION LIFT
  • Single-impeller standardized centrifugal main pumps END SUCTION BACK PULL OUT (UNI EN 12845 10.1)
  • Electric motors with spacer coupling and safety guard (UNI EN 12845:2020 10.0)
  • Diesel engines with cardan shaft coupling and guard (UNI EN 12845:2020 10.1), sized according to standard requirements (refs. UNI EN 12845 10.1 – 10.9.1 – 10.9.3)
  • Control panels with EPRO command/control unit, Ethernet connectable
  • Delivery columns sized according to UNI EN 12845 13.2.3, with inspectable check valves
  • Jockey pump complete with control circuit

Customizations

  • Configurations with 2 or more pump set modules based on required flow/head
  • Choice of positive suction/suction lift version depending on water reserve and plant layout
  • Customization of panels and signals for integration into supervision systems (Ethernet network)
  • Selection of components and delivery diameters according to specifications and UNI EN 12845 project

Applications

Shopping Centers

Cinemas and theatres

Hotel complexes

Critical infrastructure

Industries

Healthcare facilities

Residential secto

School facilities

Oil & Gas