Underground water reserves

External UNDERGROUND Tank Right Chamber - Idroelettrica Spa

Idroelettrica buried fire‑water reservoir: monobloc tanks for underground installation, pressure‑tested and protected with epoxy coatings; available in pedestrian or vehicular (drive‑over) versions and engineered with static and dynamic structural verifications.

  • Tank capacity up to 160 m³ geometric
  • Tank capacity up to 140 m³ effective
  • Light or heavy vehicular versions available

Underground firefighting water reserves are the ideal solution for storing water for fire protection systems while optimizing outdoor space and protecting the tank from weathering. Idroelettrica S.p.A. manufactures monobloc steel tanks for underground installation, fabricated under controlled procedures by qualified personnel. Welds are executed in accordance with UNI EN 287/1 qualification using IT‑SG3 welding wire to achieve high‑strength joints (up to 600 N/mm²). Each tank is pressure‑tested to 1.5 bar and protected with dedicated anti‑corrosion treatments: two‑component epoxy external coating and grey two‑component epoxy internal coating (for non‑potable use). The combination of design, internal reinforcements, and surface protections results in a robust underground tank suitable for various installation conditions.
Upon request, underground water reserves can also be designed for installations with groundwater and can be produced in vehicular versions (light or heavy traffic), in addition to the standard pedestrian-rated configuration.

Key Features

  • Monoblock steel tanks for underground installation as underground firefighting water reserves
  • Qualified UNI EN 287/1 welding with IT-SG3 wire (high strength up to 600 N/mm²)
  • 1.5 bar testing
  • External coating with two-component epoxy anti-corrosive
  • Internal coating in grey two-component epoxy (non-potable use)
  • Design with internal reinforcements sized via structural calculation

Advantages

  • Standard pedestrian-rated supply; vehicular version for light or heavy traffic available on request
  • Can be manufactured for installation with groundwater, depending on site conditions
  • Greater control and durability thanks to testing and dedicated anti-corrosive protections
  • Immediate make-up verification: overflow setup for visual inspection and waste prevention

Technical specifications

  • Design and static and dynamic verification using the limit state method, according to current laws and technical standards
  • Calculation with Enexsys code and sizing of internal reinforcements
  • Reinforcements made with high-strength sections (e.g., UPN 80, T60×60)
  • Typical equipment:
    • Galvanized steel pedestrian-rated cover
    • 700×700 mm inspection manhole with H = 500 mm
    • Ø 4” overflow sleeve
    • 2″ hydrovalve

Technical note: all reserves equipped with automatic make-up (solenoid/mechanical valves) and supplied by water mains/wells must include an overflow discharge line to allow visual confirmation of correct operation. Immediate access to the overflow allows for fault detection, prevents water waste, and reduces costs.

Customizations

  • Vehicular version for light or heavy traffic
  • Designed for groundwater conditions
  • Configurations and setups based on the system (connection diameters, make-up accessories, overflow management)

Applications

Shopping Centers

Cinemas and theatres

Hotel complexes

Critical infrastructure

Industries

Healthcare facilities

Residential secto

School facilities

Oil & Gas